IS-III Active Fixture
IS-III active implant is structured to maximize initial stability and facilitate faster osseointegration with its scientifically proven SLA surface and fixture body design.
Features
-Micro Groove
Minimize boneloss and maintain bone level by treating superior area of fixture
-S.L.A. Surface
Improvement of process technology of S.L.A surface
-Apex
Excellent to both immediate placement and immediate loading
-0.9 Pitch
Increasecontact area between thread pitch and results in increasing of stability and osseointegratiov
-Magic Thread
Specially designed to endure vertical and lateral force
-Wide Cutting Edge
Improvement of fixation and increaseclinician's comfort when placing implants by widening cutting edge area
-Micro groove2
Minimize Bone Loss
Micro groove that created on the fixture platform area prevents bone loss by improving of gum support sealing.
-Implemented micro groove
-Increase sealing of soft tissue
-Minimize bone loss by securing gum support through soft tissue integration.
Minimize bone loss and maintain bone level by treating superior area of fixture and Bevel area with open thread design promote osseointegration from cortical bone to bone level.
- Bevel area with open thread design
Maintain bone level and minimize resorption.
Progress of osseointegration from cortical bone to superior area of fixture.
-Reduce fracture risk
Increase thickness more than 2 times in comparison to IS-II Active (Criteria: 4.0 Fixture) Maintain more than 3mm around connection.
Increase strength of connection.
Reduce any fracture risks around connection.
-Micro groove
Minimize Bone Loss
Micro groove that created on the fixture platform area prevents bone loss by improving of gum
support sealing.
-Implemented micro groove
- Increase sealing of soft tissue
-Minimize bone loss by securing gum support through soft tissue integration.
-Wide Cutting Edge
Minimize Bone Loss
Improvement of fixation and increase clinician's comfort when placing implants by widening cutting edge area 2 times compared to IS-II Active.
-Widening cutting edge surface 2 times compared to IS-II Active.
-Improving self tapping by reducing pressure that applied to bones.
- Maximize initial fixation. (Any Time Loading)
-0.8 Pitch 0.9 Pitch
Minimize Bone Loss
Increase contact area between thread pitch and bone results in increasing of stability and osseointegration
Alteration of thread pitch to 0.9.
Minimize bone compression. (Prevent bone necrosis)
-Provide optimum osseointegration condition. - Widening cutting edge surface 2 times compared to IS-II Active.
-Crestal Macro Thread Design
-Self-Compactable Apex
-Powerful Deep Thread
- Micro Groove Design Internal Conical Connection
-Powerful Deep Thread
-Conical Seal 11°
- Internal Conical Connection