XN-2000V It’s time for veterinary excellence
Fully customisable instrument set-up including species-specific rules for rerun and reflex analyses
Unique gating functionality to create user-defined analysis gates and new species profiles
Comprehensive list of parameters from small sample volumes with the XN-V ‘Low Aspiration’ mode
Cost-efficient and convenient internal and inter-laboratory QC combined in one run
Enhanced productivity by automated tube sampling from volumes as small as 250 μL
With the Sysmex XN-V Series, you can deliver diagnostic results of the highest quality and value. Both the XN-1000V and XN-2000V are efficient, offer consistently reliable and secure results and can be customised or up-scaled whenever you need.
Since diagnostic information needs to be provided for a wide range of species, we have predefined nineteen commonly tested animal species for you. Additionally, you can define your own settings as needed, either for research purposes and/or to provide additional diagnostic value. Online quality control ensures your new analyser is reliable and efficient. An optical platelet count, reticulocyte parameters and body fluid analysis offer additional diagnostic insight, where needed.
*Technical Specifications :
-Species : Mouse, rat, dog, NHP, rabbit, cat, horse, cattle, pig, mini pig, Guinea pig, gerbil, camel, dolphin, marmoset, ferret, sheep, goat, hamster, bird
-Strain species : Mouse 1-15, rat 1-10, NHP 1-10, rabbit 1-5, dog 1-5, pig 1-5
-Customisable free species settings : Free 1-99
-Measurement modes : Whole blood (WB) mode / Low aspiration volume (LA) mode / Low WBC (LW) mode / Pre-diluted (PD) mode / Body fluid (BF) mode**
-Aspiration volume : 88 µL in WB and BF measurement modes / 70 µL in PD measurement mode / 50 µL in LA measurement mode
-Throughput : XN-2000V
200 samples/h in WB mode (CBC+DIFF)
166 samples/h in WB mode (CBC+DIFF+RET**)
40 samples/h in BF mode**
-Technologies : Fluorescence flow cytometry / Hydrodynamically focused impedance measurement / Cyanide-free SLS haemoglobin method / Adaptive cluster analysis system (ACAS) and special three-dimensional shape recognition analysis of each WBC subpopulation
-Quality control : XN CHECK / XN CHECK BF**
-Calibrator : XN CAL
-Standard parameters : XN-CBC
WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV,
PDW, MPV, P-LCR, PCT, NRBC %, NRBC#, MicroR*, MacroR*
/XN-DIFF
NEUT%, NEUT#, LYMPH%, LYMPH#, MONO%, MONO#, EO%, EO#, BASO%, BASO#
-Optional parameters :
RET
RET%, RET#, PLT-O, IRF, LFR, MFR, HFR, RET-He , HYPO-He*, HYPER-He*
/XN-BF
WBC-BF, RBC-BF, PMN%, PMN#, MN%, MN#, TC-BF#, RBC-BF2*
/PLT-F
PLT-F1, IPF1, WBC2, RBC2,,H-RBC*,2, PLT2
-Configurations : XN-1000V, XN-2000V. / Both models can be equipped with individually chosen clinical insight applications RET and/or XN-BF.
-Data storage : 30,000 samples
-Supported sample tubes : Regular tubes, raised bottom tubes (RBT), micro collection tubes
-Sample security : Duplicate barcode reading
-Reagent management : Available
-User management : Available
-Customisable rules : Available
*Non-mammalian analysis : Analysis parameters and Channel :-
-WBC : PLT-F channel
-RBC : PLT-F channel
-H-RBC (haemolysed RBC) : PLT-F channel
-HGB : SLS-Hemoglobin method
-HCT : RBC particle size distribution
-MCV : RBC particle size distribution
-MCH : RBC particle size distribution
-MCHC : RBC particle size distribution
-PLT : PLT-F channel
-RDW-SD : RBC particle size distribution
-RDW-CV : RBC particle size distribution
-RBC-O : RET channel