-Vantage Galan 3T—The quiet achiever!
Delivers patient focused MRI with intelligent image quality and speed
One of the quietest and most patient friendly 3T MRI systems available, and an intelligent system as well. Vantage Galan 3T not only produces stunningly crisp and beautiful images, the combination of intelligent AI, Parallel Imaging, Compressed Sensing and new workflow solutions, means whole body images can be captured quickly and efficiently to help you breeze through your day. Tackle complex procedures with automated slice alignment and rapid scan technology, and use our unique AI, AiCE to remove noise and improve SNR1 or PiQE to increase resolution2, to assist your diagnostic decision making. Delivering intelligence to you and your patients, Vantage Galan 3T is truly a quiet achiever.
-1AiCE provides higher SNR compared to typical low pass filters
-2PIQE is 510(k) Cleared for Brain and Knee regions on the Vantage Galan 3T
-Advanced Intelligence, Supreme Productivity
Vantage Galan 3T delivers superb MR performance every day for exceptional patient and staff experience. Real-time Platform integrates system components including new magnet, gradient coil and RF technology, and realizes optimized MRI performance.
-Quiet intelligence and reimagined workflow for the 3T MRI Suite
Vantage Galan 3T delivers reimagined workflow with quiet and intelligent imaging technology to optimize the MRI experience for patients and staff.
Intelligent MRI:
-AiCE MR Deep Learning reconstruction technology produces stunning MR images that are exceptionally detailed and with the low-noise properties you might expect of a higher SNR1 image. With AiCE now expanding across a broad range of anatomies, contrast and applications.
-PiQE2 is Canon Medical’s high resolution Deep Learning Reconstruction for MRI. PiQE increases matrix size, removes noise, and delivers sharp anatomical images to take MR imaging to the next level
-Combined with accelerated scan technologies, AiCE intelligently expands your capabilities to help reduce time while still producing stunning images
-Advanced post processing capability with Olea Medical and CMI technologies enhances intelligent diagnostic decision making
Quick MRI:
-Now with Compressed SPEEDER for 2D and 3D, rapid scan technologies to help you reduce scan time
-Auto Scan Assist standardizes your workflow with automated slice alignment for a range of anatomical examinations. Now with AI1 productivity is advanced to enhance procedural efficiency.
-Prioritize workflow and organizational efficiency with the Application for Tablet UX; remotely monitor scans in progress while also registering and preparing your next patient
-Optimize efficiency with Ceiling Camera and Intelligent Monitor to confirm coil set up and assist with patient positioning.
Quiet MRI:
-Short magnet and 71 cm bore offers an open MRI scanning environment
-Pianissimo technology delivers whisper quiet scan sequences
-Address challenging patients with motion and distortion correction, free breathing contrast agent free applications.
-Optimized System
Along with a new Real-time Platform, key system components such as the magnet and gradient coil have been fully optimized to produce outstanding real time MR imaging performance.
Key Features:
-High quality magnet manufactured in Japan
-Cross pattern supported gradient coil
-Integrated RF technology
-Total optimization with Real-time Platform
-Enhanced system stability with
High-quality magnet manufactured in Japan
The first made-in-Japan 3T magnet enables a reduction in the quench rate with its high manufacturing quality and unique Partitioned Superconducting Wire Structure. This also expands FOV while maintaining a high magnetic field homogeneity, allowing more information to be obtained in a single scan while stabilizing the image.
-High efficiency performance with
Cross-pattern supported gradient coil
Refined gradient coil technology optimizes consistent image quality through increased gradient stability and precise center frequency control. This enhances power efficiency and suppresses vibration and acoustic noise during the examination
-Total optimization with
Real-time Platform
State-of-the-art platform that provides stable system performance with high-speed processing by advanced Real Time Manager.
-Advanced intelligent Clear-IQ Engine (AiCE)
Harness the power of deep learning to enable enhanced resolution and achieve fast imaging.
Advanced intelligent Clear-IQ Engine (AiCE) intelligently removes noise from images which results in higher SNR1 and enhanced resolution. Achieve sharp, clear and distinct images utilizing the power of Deep Learning.
-Precise IQ Engine (PIQE)2
Achieve PIQE imaging for MRI
Precise IQ Engine (PIQE) is Canon Medical’s high resolution Deep Learning Reconstruction for MRI. PIQE increases matrix size, removes noise, and delivers sharp anatomical images to take MR imaging to the next level.
-Reach a new PIQE in MRI
Deep Learning technology helps deliver clear, sharp and distinct images. Acquiring high-resolution images traditionally required long scan time. However, with PIQE, high-resolution images are obtained with the same scan time as conventional scans.
-Achieving quick and high SNR1 images is now possible with Canon’s intelligent new technologies
AiCE combines with rapid scanning to help you boost productivity in combination with unique Canon scan acceleration technologies like Compressed SPEEDER, you have the ability to focus on faster scans and SNR by removing noise from images.
-Exsper
Exsper is a robust parallel imaging technique that provides accelerated scans. Designed to suppress unfolding errors even in small FOV images, delivering exceptional imaging performance with its highly reliable and fast scanning technology. Exsper can be combined efficiently with other applications such as AiCE.
-Multi-Echo UTE
Multi-Echo UTE utilizes a unique sampling pattern which enables the ability to acquire a very short TE in one scan, with the benefit of obtaining signals with short T2* values. Multiple data with different short TE values are also expected to see the variance in short T2* range or to create T2* mapping of tissues.
-MR Elastography (MRE)
The role of MRE has been increasingly recognized in multidisciplinary clinical guidelines for noninvasive liver fibrosis assessment, particularly in suspected cases of non-alcoholic fatty liver disease (NAFLD).
-Non-invasive fat imaging and quantification
Imaging is rapidly becoming the standard for fat quantification. Canon’s fat imaging and quantification can simultaneously, in a single breath held exam, provide quantitative maps of the liver to measure proton density fat fraction (PDFF) and R2*.
Positioning flexibility:
-Multiple coils can be used simultaneously, creating flexibility for operators and comfort for patients
-Convenient port locations mean that a large segment of exams can be performed feet first
-205 cm of table movement coupled with a sliding spine coil provides maximum flexibility for operators and greater comfort for patients.
-Improve imaging robustness to enhance diagnostic capability
Many patient situations present challenges with motion artifacts and distortion and contrast agent allergies.
With clever approaches to these issues, the Vantage Galan 3T delivers diagnostically relevant images to help you avoid re-scans.
-Iterative Motion Correction (IMC)
IMC is a motion correction technology for reducing motion artifacts caused by sporadic movements. IMC utilizes Deep Learning based methods for motion correction in addition to traditional model-based correction.
-Zoom DWI
Diffusion weighted image with small FOV can be acquired suppressing distortion and unfolding errors, diagnostic reliability is expanded.
-4D Flow imaging
4D flow MRI offers the ability to measure and to visualize the temporal evolution of complex blood flow patterns within an acquired 3D volume.
*For 4D Flow imaging, analysis software is required. This image is using the software provided by Pie Medical Imaging.
-pseudo-Continuous Arterial Spin Labeling (pCASL)
Arterial Spin Labeling (ASL) MRI provides non-invasive methods to acquire perfusion weighted images without the use of external agents. pCASL utilizes a fast spin echo (FSE) readout which makes it less sensitive to susceptibility artifacts.
-Free breathing with Quick Star
Quick Star reduced motion artifacts can be helpful for challenging patients that have difficulty holding their breath or especially for liver examination.
-Non-Contrast MRA
An increasing awareness of the potential risks associated with gadolinium-based contrast agents has revealed the need for alternative, contrast-free MRA techniques. Non-contrast MRA sequences minimize risk to patients with sensitivity to contrast while producing exceptional diagnostic images.
-Reverse encoding Distortion Correction DWI (RDC DWI)
Reverse encoding Distortion Correction DWI (RDC DWI) is intended to reduce distortion in phase encoding direction due to B0 field inhomogeneity or eddy current, in DWI sequence.