Integrated CT-linac - uRT-linac 506c is Next generation of personalized precision radiotherapy is empowered by the utilization of IGRT based on high-quality diagnostic CT with a new radiotherapy clinical workflow.
- Fully Integrated, Highly Precise Radiotherapy System
- Integrated Design , Coaxial alignment of the diagnostic CT and linear accelerator with a shared table for precise treatment. It supports the entire RT workflow from CT simulation to CT image guidance and treatment delivery.
- Sophisticated Algorithm Enabled System , Digital system architecture, ultra-wide 544° gantry angle span, 1400 MU/min dose rate, 120-leaf dynamic high-resolution MLC, and a sophisticated Monte Carlo Dose calculation algorithm.
- Universal and Flexible Radiation Delivery , Supports all advanced radiotherapy applications, such as uARC®, sIMRT, dIMRT, 4D-CT, non-coplanar, and respiratory gating therapy.
- High-Quality CT-IGRT
- Superior CT Imaging
- Gold Standard Dose Calculation
- Image Guidance Positioning Accuracy
- On-line Monitoring of Target Area Changes
- Intelligent Auto-Contouring , Supports more than 100 OAR and target volume models for lung, rectal, and cervical cancers.
- Integrates various treatment planning strategies such as 3D dose modelling, beam orientation optimization, and auto-optimization and allows for one -click treatment plan generation. Autoplan helps improve treatment planning efficiency and quality consistency.
- Intelligent EPID QA system enables efficient, precise and easy-to-use Machine QA, Plan QA, 2D invivo* and 3D invivo*.
- *2D invivo: Dose real-time monitor and warning through the treatment course.
- *3D invivo: 3D dose reconstruction after the treatment.
- ntelligent Treatment , The innovative unified trajectory generation process and system* can generate a smooth beam trajectory for moving components, ensuring treatment delivery accuracy and efficiency.
The virtual 3D collision detection system can monitor the patient's position in real-time for collision avoidance.
- uRT-linac 506c offers a more precise, efficient, and patient friendly radiotherapy. The entire workflow of radiotherapy, including simulation, contouring, plan, treatment and QA, can be developed or modified online to facilitate individualized precision radiotherapy and a one-stop RT solution.
- Online Adaptive Radiotherapy
- One-Stop RT Solution
* Technical Details :-
* Diagnostic CT System:-
Scanner Aperture:87 cm
Detector Rows:40
Standard FOV:63 cm
Longest scanning distance:91 cm
Application:CT-IGRT, 4D CT, Low dose CT, CT-sim
* RT System :-
Gantry Speed:7 °/s
Isocenter Accuray:0.5 mm
Dose Rate:FF:600 MU/min FFF: 1400 MU/min
MLC Speed:6.5 cm/s
MLC Width:5mm
MLC Field Size:40cm × 40cm
Treatment Table:4D/6D
*Not FDA or CE marked, not commercially available in the U.S. or the EU.