-Solve pollution from the source
During dental surgery, a lot of bacteria-containing aerosols are generated around the dental chair the method of air circulation have no effect on these invisible enemies.
The only way is to solve the pollution from the source, should adopt the suction machine of advanced technology such as negative pressure semi-dry type, two-stage separation type. It has a suction efficiency of 300 liters per minute, instantly sucking the bacterial aerosol in the patient's mouth, and preventing bacterial contamination at the source.
-Without negative pressure system
-With negative pressure system
-Since then your clinic will be filled with fresh air
Studies have shown that the number of bacteria in the clinic's air (including hepatitis B, tuberculosis, etc.) has risen linearly within 2 hours after the consultation, and it can be predicted that the number of bacteria in the clinic will continue to increase with the number of operations during the day. Dentists and nurses who have been exposed to bacterial contamination for up to 2 meters for a long time are even more susceptible to infection than individual patients.
Runyes suction machine adopts the most advanced negative pressure semi-dry system at present, which can effectively control the number of bacterial after operations, and it will be stable below the safety standard of 200cfu / m3. Since then your clinic will be filled with fresh air.
-Without negative pressure system
-With negative pressure system
-Specification model: ENROLL-01
-It can supply up to: 1treatment site
-It can be used by up to: 1dental unit
-Suction force: 300L/min
-Maximum vacuum: -37KPa
-Host voltage : AC230V
-Rated current: 3.7~4.4A
-Vacuum regulation: -20KPa
-Specification model: ENROLL-05
-It can supply up to: 5treatment site
-It can be used by up to: 3dental unit
-Suction force: 900L/min
-Maximum vacuum: -37KPa
-Host voltage : AC230V
-Rated current: 3.5~4A
-Vacuum regulation: -20KPa
-Specification model: ENROLL-08
-It can supply up to: 8treatment site
-It can be used by up to: 6dental unit
-Suction force: 1500L/min
-Maximum vacuum: -37KPa
-Host voltage : AC230V
-Rated current: 4.5~5A
-Vacuum regulation: -20KPa
-Specification model: ENROLL-01
-Noise: 50DB
-Frequency: 50~60Hz
-Motor power: 550W
-Motor speed: 3440 rpm
-Inverter power:
-Intake tube size: 32mm
-Net weight: 32Kg
-Size: 330×540×620mm
-Specification model: ENROLL-05
-Noise: 59DB
-Frequency: 0~70Hz
-Motor power: 630W
-Motor speed: 3980 rpm
-Inverter power: 750 w
-Intake tube size: 32mm
-Net weight: 33Kg
-Size: 410×510×610mm
-Specification model: ENROLL-08
-Noise: 61DB
-Frequency: 0~65Hz
-Motor power: 1300W
-Motor speed: 3740 rpm
-Inverter power: 2200 w
-Intake tube size: 32mm
-Net weight: 37Kg
-Size: 410×510×630mm